Public registry
Nodes
Browse canonical concepts by label, domain, node type, prefix and encoded class.
Current membership scope: Base domain only
| Concept | Node type | Base domain | Matched membership | Identifier |
|---|---|---|---|---|
| Serum Chloride Measurement | Biochemical test | Laboratory Medicine | Base domain | AMW:TECH:080003 |
| Serum Creatinine Concentration Serum creatinine is a renal function laboratory parameter used in kidney injury and organ dysfunction scoring. | Parameter | Laboratory Medicine | Base domain | AMW:PARAM:125008 |
| Serum Cystatin C Concentration | Parameter | Laboratory Medicine | Base domain | AMW:PARAM:125031 |
| Serum Cystatin C Measurement | Biochemical test | Laboratory Medicine | Base domain | AMW:TECH:080009 |
| Serum Lactate Dehydrogenase Activity Serum LDH is a tissue injury enzyme parameter used in clinical severity criteria. | Parameter | Laboratory Medicine | Base domain | AMW:PARAM:125009 |
| Serum Magnesium Concentration | Parameter | Laboratory Medicine | Base domain | AMW:PARAM:125028 |
| Serum Magnesium Measurement | Biochemical test | Laboratory Medicine | Base domain | AMW:TECH:080006 |
| Serum Osmolality | Parameter | Laboratory Medicine | Base domain | AMW:PARAM:125038 |
| Serum Osmolality Measurement | Biochemical test | Laboratory Medicine | Base domain | AMW:TECH:080016 |
| Serum Phosphate Concentration | Parameter | Laboratory Medicine | Base domain | AMW:PARAM:125029 |
| Serum Phosphate Measurement | Biochemical test | Laboratory Medicine | Base domain | AMW:TECH:080007 |
| Serum Potassium Concentration | Parameter | Laboratory Medicine | Base domain | AMW:PARAM:125026 |
| Serum Potassium Measurement | Biochemical test | Laboratory Medicine | Base domain | AMW:TECH:080002 |
| Serum Sodium Concentration | Parameter | Laboratory Medicine | Base domain | AMW:PARAM:125025 |
| Serum Sodium Measurement | Biochemical test | Laboratory Medicine | Base domain | AMW:TECH:080001 |
| Serum Uric Acid Concentration | Parameter | Laboratory Medicine | Base domain | AMW:PARAM:125030 |
| Serum Uric Acid Measurement | Biochemical test | Laboratory Medicine | Base domain | AMW:TECH:080008 |
| Signal-To-Noise Ratio The comparison of the quantity of meaningful data to the irrelevant or incorrect data. | Instrument calibration method | Laboratory Medicine | Base domain | AMW:TECH:050329 |
| Silver Staining The use of silver, usually silver nitrate, as a reagent for producing contrast or coloration in tissue specimens. | Microbiology test | Laboratory Medicine | Base domain | AMW:TECH:010125 |
| Sims–Huhner test determination of sperm count and motility in a sample taken from the cervical canal within an hour of intercourse | Laboratory Test | Laboratory Medicine | Base domain | AMW:INV:115005 |
| Skin Irritancy Tests Tests or bioassays that measure the skin sensitization potential of various chemicals. | Diagnostic assay | Laboratory Medicine | Base domain | AMW:TECH:050734 |
| Skin Test End-Point Titration A quantitative form of intradermal testing for the relative allergenicity of a substance. It is used to determine the amount of an allergen that will… | Laboratory Test | Laboratory Medicine | Base domain | AMW:TECH:010205 |
| Skin Tests Epicutaneous or intradermal application of a sensitizer for demonstration of either delayed or immediate hypersensitivity. Used in diagnosis of hyper… | Laboratory Test | Laboratory Medicine | Base domain | AMW:TECH:010202 |
| Slit Lamp Microscopy A procedure that uses a SLIT LAMP to examine structures in the front of the EYE, such as the CONJUNCTIVA; CORNEA; IRIS; and AQUEOUS HUMOR. | Microscopy method | Laboratory Medicine | Base domain | AMW:TECH:010574 |
| Solid Phase Extraction An extraction method that separates analytes using a solid phase and a liquid phase. It is used for preparative sample cleanup before analysis by CHR… | Analytical chemistry method | Laboratory Medicine | Base domain | AMW:TECH:050043 |
| Solid Phase Microextraction A solventless sample preparation method, invented in 1989, that uses a fused silica fiber which is coated with a stationary phase. It is used for sam… | Analytical chemistry method | Laboratory Medicine | Base domain | AMW:TECH:050044 |
| Sonication The application of high intensity ultrasound to liquids. | Analytical chemistry method | Laboratory Medicine | Base domain | AMW:TECH:050702 |
| Sound Spectrography The graphic registration of the frequency and intensity of sounds, such as speech, infant crying, and animal vocalizations. | Analytical chemistry method | Laboratory Medicine | Base domain | AMW:TECH:050703 |
| Specimen Handling Procedures for collecting, preserving, and transporting of specimens sufficiently stable to provide accurate and precise results suitable for clinica… | Specimen processing method | Laboratory Medicine | Base domain | AMW:TECH:010251 |
| Spectrometry, Fluorescence Measurement of the intensity and quality of fluorescence. | Analytical chemistry method | Laboratory Medicine | Base domain | AMW:TECH:050128 |